Department of Mechanical Engineering, Collage of Engineering, University of Baghdad, 10071 Baghdad, Iraq
10.30772/qjes.2023.143262.1030
Abstract
Air-conditioning systems (ACs) are essential in hot and humid climates to ensure acceptable ambient air quality as well as thermal comfort for buildings users. It is essential to improve refrigeration system performance without increasing the effects of global warming potential (GWP) and ozone depletion potential (ODP). The main objective of this study is to evaluate the performance of an air conditioning system that operates with a liquid suction heat exchanger (LSHX) through implementing refrigerants with zero OPD and low GWP (i.e., R134a and R1234yf). Liquid suction heat exchanger (LSHX) was added to an automobile air conditioning system (AACS).When Liquid suction heat exchanger was added to the cycle, primary results indicated that an enhancement in the cycle coefficient performance (COP) by 25.2 %and 17.3% for R134a and R1234yf respectively, and decreasing in mass flow rate of the refrigerants used (m ̇_r). Also increasing in refrigeration effect (RE) by 4.2% and 2.3% for R134a and R1234yf respectively. Presence of LSHX caused increasing in heat rejected by condenser (Qcond.) according to increasing in sub-cooling degree and decreasing in compressor work (Wcomp.), increasing in condenser exergy destruction (X. des. cond.) and thermostatic expansion device (TXV) exergy destruction, but decreasing in compressor and evaporator. Summary of previous experimental and numerical studies is presented as well.
Tritjahjono, R.I. , Sumeru, k. , Setyawan, A., and Sukri , M.F.,(2019). Evaluation of Subcooling with Liquid-Suction Heat Exchanger on the Performance of Air Conditioning System Using R22/R410A/R290/R32 as Refrigerants. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences . Vol. 55, Issue 1, pp. 1–11.
Nagasai, B.P, Kumar. K.D., Reddy, CH.CH., Rao, T.S.,(2020). Experimental Investigation on Performance of Vapour Compression Refrigeration System with Integrated Sub-Cooling. Test engineering & management. Vol. 83, Issue November, pp. 5104-5111.
Joshi , Y.,Zanwar, D., Joshi, S., (2021) . Performance investigation of vapor compression refrigeration system using R134a and R600a refrigerants and Al2O3nanoparticle based suspension. Materials Today: Proceeding. Vol.44, pp. 1511–1519. doi:10.1016/j.matpr.2020.11.732 10.1016/j.matpr.2020.11.732
T.O., Akinlabi, S.A., Madyira, D.M., (2018).Enhancing the Performance of Vapour Compression Refrigeration System using Nano Refrigerants. IOP Conf. Series: Materials Science and Engineering. ICESW 2018. Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/413/1/012068
Bilir, N., Ersoy, H.K.,(2009). Performance improvement of the vapour compression refrigeration cycle by a two-phase constant area ejector. International Journal of Energy Research. Vol. 33, Issue 5, pp. https://doi.org/10.1002/er.1488
Khan, J.R., Zubair, S.M.,(2000). Design and rating of an integrated mechanical-subcooling vapor-compression refrigeration system. Energy Conversion and Management . Vol. 41,Issue 11,pp. 1201-1222. https://doi.org/10.1016/S0196-8904(99)00169-7
Djuanda, D., (2018). Performance study of double pipe internal heat exchanger in R-410a air conditioning system. in AIP Conference Proceedings. https://doi.org/ 10.1063/1.5046592
Mota-Babiloni, A., Esbrí, J.N., Miralles, V.P., Cervera, A.B., and Maiorino, A.,(2019). Experimental influence of an internal heat exchanger (IHX) using R513A and R134a in a vapor compression system . Applied Thermal Engineering .Vol. 147,pp. 482-491. https://doi.org/10.1016/j.applthermaleng.2018.10.092
Alhendal, Y., ,Gomaa, Ab., ,Bedair, G., and Kalendar, A., ,(2020).Thermal Performance Analysis of Low-GWP Refrigerants in Automotive Air-ConditioningSystem. Advances in Materials Science and Engineering. Vol. 2020 https://doi.org/10.1155/2020/7967812 .
Gungor, U., Hosoz. M., (2021). Experimental performance evaluation of an R1234yf automobile air conditioning system employing an internal heat exchanger . International Journal of Automotive Engineering and Technologies .Vol. 10,Issue 1, pp. 50_59. https://doi.org/10.18245/ijaet.842426
Sharif, M.Z., Azmi1, W.H., Zawawi. N.N M., Mamat, R., and Hamisa, A.H.,(2020). R1234yf vs R134a in automotive air conditioning system: A comparison of the performance. In in IOP Conference Series: Materials Science and Engineering. Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/863/1/012049
Mahmood, R.A.,(2020). Case study of liquid suction heat exchanger in a mechanical refrigeration system using alternative refrigerants. International Journal of Engineering & Technology. 9 ,Issue 3,pp. 644_649. https://doi.org/10.14419/ijet.v9i3.30777
Qian S., Yu J., Yan G.,(2017). A review of regenerative heat exchange methods for various cooling technologies. Renewable and Sustainable Energy Reviews. Vol. 69 , Issue November 2016 ,pp. 535-550
Abdulmajeed, B.A., Jawad, H.R., (2019). Analysis of Shell and Double Concentric Tube Heat Exchanger Using CFD Application. Journal of Engineering. Vol. 25,Issue 11, pp. 21 _36. https://doi.org/10.31026/j.eng.2019.11.02
Wantha, CH.,(2019). Analysis of heat transfer characteristics of tube-in-tube internal heat exchangers for HFO-1234yf and HFC-134a refrigeration systems. Applied Thermal Engineering .Vol. 157, Issue October 2018 ,pp. 113747. https://doi.org/10.1016/j.applthermaleng.2019.1137.
Shah, Z.A., Zheng, Q., Mehdi, Gh., Ahmad N., Waleed, R., Rehman, A.U., and Raza, A.,(2020).The Theoretical Framework of the Modified Organic Rankine Cycles for Improved Energy and Exergy Performances. International Energy Journal. Vol. 20, pp. 169-180
Arora, A.C., (2009) . Refrigeration and Air Conditioning . 3rd 2009. New Delhi , ISBN: 9780070083905
R., KUMAŞ, K., AKYÜZ , A. Ö., (2022). Comparative energetic analysis of a refrigeration system by using r123 and its alternative r514a refrigerants. Techno Science . Scientific Journal of Mehmet Akif Ersoy University . Vol. 5,Issue 2 ,pp. 45_50
Ghanbarpour, M., Mota‐Babiloni, A., Badran, B.E., and Khodabandeh, R.,(2021) Energy, exergy, and environmental (3E) analysis of hydrocarbons as low GWP alternatives to R134a in vapor compression refrigeration configurations. Applied Sciences (Switzerland) .Vol.11 ,Issue 13. https://doi.org/10.3390/app11136226
Mohammed,A Akeel and Sarsam,W S.. (2024). Investigation of an automobile air-conditioner with a liquid-suction heat exchanger using R134a and R1234yf. Al-Qadisiyah Journal for Engineering Sciences, 17(1), 66-76. doi: 10.30772/qjes.2023.143262.1030
MLA
Mohammed,A Akeel, and Sarsam,W S.. "Investigation of an automobile air-conditioner with a liquid-suction heat exchanger using R134a and R1234yf", Al-Qadisiyah Journal for Engineering Sciences, 17, 1, 2024, 66-76. doi: 10.30772/qjes.2023.143262.1030
HARVARD
Mohammed A Akeel, Sarsam W S.. (2024). 'Investigation of an automobile air-conditioner with a liquid-suction heat exchanger using R134a and R1234yf', Al-Qadisiyah Journal for Engineering Sciences, 17(1), pp. 66-76. doi: 10.30772/qjes.2023.143262.1030
CHICAGO
A Akeel Mohammed and W S. Sarsam, "Investigation of an automobile air-conditioner with a liquid-suction heat exchanger using R134a and R1234yf," Al-Qadisiyah Journal for Engineering Sciences, 17 1 (2024): 66-76, doi: 10.30772/qjes.2023.143262.1030
VANCOUVER
Mohammed A Akeel, Sarsam W S.. Investigation of an automobile air-conditioner with a liquid-suction heat exchanger using R134a and R1234yf. QJES. 2024;17(1):66-76. doi: 10.30772/qjes.2023.143262.1030